AP 300 Automatic Polarimeter

Beli via Whatsapp

 

Tags : Polarimeter  ATAGO 

AP-300 Automatic Polarimeter

A multifunctional automatic polarimeter at a reasonable price!

  • Measures the relative optical rotation of medical agents 
  • Measures the concentration of optically active substances found in fragrance materials or chemical compositions
  • Measures sugar by the international sugar scale and the purity of sugar
  • Identifies the attributes of inverted sugar, etc.
  • Measures the optical rotation or the concentration of optically active substances
  • NEW password function
  • NEW measurement Mode - will take advantage of measurements that you specify!
  • Compact and space saving
  • Selectable measurement readings: Angle of Rotation, International Sugar Scale (2 types), Relative Optical Rotation, Concentration, and Purity
  • Automatic measurement and digital display
  • Easy operation: Place sample tube in the AP-300 and press START
  • Out-of-range measurements are indicated instantly by graphic display
  • Manual calibration
  • Flash memory the 30 most recent records of measurement readings
Measurement Scales:Angle of Rotation, International Sugar Scale (without temperature compensation), International Sugar Scale (with automatic temperature compensation)
Measurement Readings:Angle of Rotation, International Sugar Scale (without temperature compensation), International Sugar Scale (with automatic temperature compensation). Specific Optical Rotation, Concentration, and Purity
Measurement Range:Angle of Rotation: -89.99 ~ +89.99° International Sugar Scale: -130.00~ +130.00°
Minimum Indication:Angle of Rotation: 001° 
International Sugar Scale :0.01°Z
Measurement Accuracy:Angle of Rotation:  ±0.01° 
International Sugar Scale : ±0.03°Z (Checked by reading a standard quartz plate -
Temperature Compensation
Range for International
Sugar Scale:
18.0 ~ 30.0°C
Temperature Accuracy:± 0.5° C
Display Panel:Color LCD with backlight
Graphic Display:Graphic display indicating the conformity of measurement values for measurements with limit settings.
History Function:Stores the 30 most recent records of measurement readings for later reference and printing.
Zero Setting:Zero setting can be conducted by pressing the ZERO key when the sampling chamber is empty
Manual Calibration:Enables manual calibration by measuring a standard quartz plate
Measurement Wavelength:589 nm (D-line)
Outputs:(1) DP-63 Digital printer (optional)
(2) RS-232C input/output ports for connecting to a computer system
Power Supply:AC 100V to 240V, 50/60Hz
Light Source:Halogen lamp
Accessories:(100mm,  200mm) observation tube, (1 each)