Automatic Kinematic Viscosity Tester VSC-S1102 Scitek

Hanya Tersisa 1 lagi

 


Automatic Kinematic Viscosity Tester has extremely wide-ranging practical applications in fields including petrochemicals, transportation, electric power and energy, and industrial manufacturing. As a core testing apparatus for evaluating the flow properties, lubricating and protective capabilities, and the extent of quality degradation of oils.

 

Features:

1. 8-inch HD touchscreen with a built-in MCU that independently handles data processing and automatic kinematic viscosity calculations.

2. Four independent test stations, each automatically calculates its own results, precisely maintained to 4 significant figures.

3. High-precision temperature control unit, industrial-grade PT100 platinum resistance temperature sensor, employing an advanced AI-based PID control algorithm with auto-tuning capabilities.

4. Temperature control precision of ±0.01°C and supports secondary calibration using high-precision thermometers.

5. Built-in stainless steel stirring shaft, paddle, flow guide tube, and heating element, significantly extending service life.

6. Integrated design combining the cooling unit and main instrument body, eliminating the need for a bulky external chiller.

7. Employs semiconductor (Peltier) circulating cooling technology, an additional cooling module (optional) enables low-temperature testing down to 20°C.

8. The bath features a high-brightness, high-penetration LED light at the bottom, providing excellent visibility for monitoring the liquid level in the capillary.

9. Automatically stores and prints valid test results, with internal memory capable of holding up to 9,999 data records.

10. Comes standard with dedicated viscometer clamps and a plumb-bob alignment tool.

11. Compatible with optional Pinkevitch, Ubbelohde, and reverse-flow viscometers.

12. An optional quartz glass bath allows for high-temperature testing exceeding 150°C.

13. Can also function independently as a high-precision thermostatic water/oil bath.

14. Standard compliance: ASTM D445, ISO3104, GB/T265-88.

 

Model

VSC-S1102

Display

8-inch touch screen

Capillary Tube Capacity

4

Temp. Measurement Range

RT. to 150

Temp. Measurement Accuracy

±0.01

Temp. Control Range

20–150

Temp. Control Accuracy

±0.05 °C

Temp. Display Accuracy

±0.01 °C

Stirring Speed

1250 r/min

Timing Range

0–999.9 s

Data Output

Built-in printer

Data Storage

9999

Heater Power

1500 W

Power Supply

AC 220±10%V, 50/60Hz

External Size (W×D×H)

620×320×580

Shipping Size (W×D×H)

700×400×660

N.W./G.W.

22/31 kg